This device is developed based on the principle of low-voltage ionization in a high-frequency magnetic field and includes one leak detection main unit. Its highest sensitivity can reach 0.01 ppm. It supports set-value alarm, and the alarm methods are buzzer sound reminders and changes in the concentration at the leakage point.
Item | Technical Parameters |
---|---|
Vacuum Pump Type | Double-stage Oil Pump (Customized) |
Measuring Range (SF6) | 0.01~10000ppm; (Recommended Optimal Detection Range: 0.01-100ppm) |
Measuring Accuracy (Highest Sensitivity) | 0.01ppm(v) 1.0×10-8 |
Presence of Radiation Source in the Equipment | None |
Response Time | ≤ 0.5 seconds in an environment with ≥ 1ppm of SF6 |
Recovery Time | ≤ 10 seconds in an environment with 99.99% of SF6; 1 second in an environment with 10% of SF6 |
Indication Method | Direct display of ppm value and audible alarm. The ppm value is directly displayed on the tablet with a resolution of 0.01ppm; for example, 99.99ppm. The LCD digital display of the detector: The higher the leakage concentration, the greater the digital change. Buzzer prompt: The higher the leakage concentration, the greater the change in the frequency of the buzzer sound. |
Alarm Setting Range | Any integer alarm value can be set within the measuring range |
Detector Length | 3 meters |
Continuous Working Time | ≤ 4 hours |
Power Supply | AC power supply 220V 50Hz or a lithium battery that can provide continuous operation for 3 hours |
Ambient Temperature | 5℃-45℃ |
Relative Humidity | ≤ 85% |
Power | ≤ 120w |
Overall Dimensions | 400(L)*340(B)*320(H), dimensions after the telescopic rod is retracted |
Net Weight of the Whole Machine | 13.0 ± 0.5Kg |
Equipment Fault Self-check | Unique fault detection indication points can quickly and simply determine whether the equipment is normal and whether the user is using it correctly; and simple methods for troubleshooting. |
Whether there is a User Calibration Function | Simple user recalibration and calibration functions |
Sensor Protection | A PM1.0 filter screen at the detector head to prevent micro-dust from blocking the probe, which may cause a decline in the performance of the instrument. |
Sensor Life | Not less than 5 years |
Warranty | One-year warranty for the whole machine, including the sensor |
Serial Number | Name | Unit | Technical Specification | Quantity |
---|---|---|---|---|
1 | O-shaped Seal Ring | Piece | 10*2 | 2 |
2 | O-shaped Seal Ring | Piece | 6*1 | 2 |
3 | Fuse Tube | Piece | 0.5A | 2 |
4 | Fuse Tube | Piece | 5A | 2 |
5 | Dedicated PM1.0 Filter Cartridge | Set | KSLH-P1 | 2 |
6 | Flathead Screwdriver (for Adjusting Knob) | Piece | 3*100 | 1 |
7 | Power Cord | Piece | 30.753 | 1 |
8 | Vacuum Pump Oil | Bottle | 250ml | 1 |
9 | Moisture Removal and Correction Module | Piece | Optional |